• Main Menu
(727) 328-0268 info@ambienttech.com
Free Consultation
ambienttech.com
  • Home
  • About
  • Services
    Core Drilling Services View all services →
    Environmental & Remediation Drilling Geotechnical Drilling CPT & In-Situ Testing Monitoring-Well Installation
    Geophysical Surveying Utility Location & Mapping Concrete Coring Solar Groundwater Monitoring Solar Power for Remediation
  • Projects
  • Service Areas
    • St. Petersburg
    • Tampa
    • Lakeland
    • Orlando
    • Pasco County
    • Sarasota
    • Bradenton
    • Fort Myers
    • Lake Okeechobee
  • News
  • Careers
  • Contact
ambienttech.comambienttech.com
  • Home
  • About
  • Services
    • Environmental & Remediation Drilling
    • Geotechnical Drilling
    • Cone Penetration Testing and In-Situ Testing
    • Monitoring-Well Installation
    • Geophysical Surveying Services
    • Underground Utilities Location, Designation and Mapping
    • Concrete Coring
    • Solar-Powered Groundwater Monitoring Systems
    • Solar Power Systems for Engineering & Remediation
  • Projects
  • Service Areas
    • St. Petersburg
    • Tampa
    • Lakeland
    • Orlando
    • Pasco County
    • Sarasota
    • Bradenton
    • Fort Myers
    • Lake Okeechobee
  • News
  • Careers
  • Contact
Project experience

Sunrise Development Site — Brooksville, FL

ATI Geologica was appointed by WSP to complete three Cone Penetration Tests to 100 ft or refusal near South Brooksville, FL to investigate the suitability of installing a groundwater well. The tests were performed using a track-mounted CPT rig anchored using helical anchors. An electronic piezocone collected data continuously until refusal in bedrock at approximately 65 feet below ground surface (ft bgs). The data…

  • LocationBrooksville, FL
Sunrise Development Site — Brooksville, FL project
Projects / Sunrise Development Site — Brooksville, FL
Scope and field context

Project scope and field context

ATI Geologica was appointed by WSP to complete three Cone Penetration Tests to 100 ft or refusal near South Brooksville, FL to investigate the suitability of installing a groundwater well. The tests were performed using a track-mounted CPT rig anchored using helical anchors. An electronic piezocone collected data continuously until refusal in bedrock at approximately 65 feet below ground surface (ft bgs). The data was then processed and produced into a factual data report summarizing the results and including highlights, a comprehensive evaluation of the subsurface and typical engineering parameters including SPT-N value equivalents. Each sounding ran continuously without disturbance or interruption. The limestone bedrock was encountered at the expected depth. The CPT sounding locations were relatively closely spaced and had distinctly different profiles. CPT was useful in detecting the various changes in material in great detail and the client was pleased with the information provided.

Related services

Cone Penetration Testing & In-Situ Testing

Project categories

InSitu Testing Including CPT
From the field

Project images

Sunrise Development Site — Brooksville, FL project image
Sunrise Development Site — Brooksville, FL project image
Plan the next field program

Need experience aligned with your site and scope?

Share the location, requested methods, depths, quantities, and schedule for project-team review.

Start a project conversation
Ambient Technologies, Inc.

Ambient Technologies is a certified MBE, DBE and SBE contractor, employee-owned and headquartered in Florida. We provide environmental, geotechnical and geophysical field services across the Americas.

Learn about Ambient Technologies
Core Services
  • All Services
  • Environmental & Remediation Drilling
  • Conventional Geotechnical Drilling
  • Cone Penetration Testing & In-Situ Testing
  • Monitoring-Well Installation, Relocation & Abandonment
Specialized Services
  • Geophysical Surveying
  • Underground Utility Location, Designation & Mapping
  • Concrete Coring
  • Solar-Powered Groundwater Monitoring
  • Solar Power for Engineering & Remediation
Contact Us
  • Phone: (727) 328-0268
  • Fax: (727) 328-2477
  • 5709 First Avenue South
    Saint Petersburg, FL 33707
  • info@ambienttech.com
Copyright 2026 by Ambient Technologies, Inc. |Privacy Statement|Terms Of Use
|Login
Powered by: QuickSocial